5-20
Confidential
1.3.12 Set PC print functions (function code: 43)
<Function>
This function is used to change the settings of the various print functions summarized in the
table below.
<Operating Procedure>
Setting functions
LCD Description Set value Default
Manual Feed Manual feed setting On/Off Off
Resolution Print resolution 300/600/1,200 dpi 600 dpi
Toner Save Toner save mode setting On/Off Off
Density Density (printing density) level
setting
-6 to 6 0
JB-Can Time Time until host timeout after a job
is canceled
0 to 225 seconds 4 seconds
Sleep Time Time until sleep mode is entered 0 to 99 minutes 5 minutes
Page Protection Page memory setting Off/Letter/A4/Legal/Auto Off
Emulation Emulation (print language)
setting
Auto/HP/PS Auto
Auto I/F Time Interface open time setting 1 to 99 seconds 5 seconds
Media Type Paper type setting Thin/Plain/Thick/
Thicker/Trancparency/
Recycled/Bond/
Envlopes/EnvThin/
EnvThick
Plain or Thin
Paper Size Image development area setting Letter/Legal/A4/
Executive/ISOB5/JISB5/
A5/ISOB6/A6/Monarch/
C5/COM10/DL/DLL/
A4Long/Postcard/Folio
Letter or A4
Copies Number of copies 1 to 99 copies 1 copy
For models without keypad
(1) Press the [▲] or [▼] key in the initial
state of maintenance mode to display
"MAINTENANCE 43" on the LCD, and
press the [OK] key. "Manual Feed" is
displayed on the LCD.
(2) Press the [▲] or [▼] key to display the
function you want to change the setting
of, and press the [OK] key.
(3) For fixed parameters (On/Off, etc.),
press the [▲] or [▼] key to display the
setting you want to apply, and press the
[OK] key.
(4) When the [Stop] key is pressed, the
machine returns to the initial state of
maintenance mode.
For models with keypad
(1) Press the [4], and then the [3] key in the
initial state of maintenance mode.
"Manual Feed" is displayed on the LCD.
(2) Press the [▲] or [▼] key to display the
function you want to change the setting
of, and press the [SET] or [OK] key.
(3) For fixed parameters (On/Off, etc.),
press the [▲] or [▼] key to display the
setting you want to apply, and press the
[SET] or [OK] key. For parameters
requiring numerical value entry, use the
keypad to enter a numerical value
directly, and press the [SET] or [OK] key.
(4) When the [X] or [Stop] key is pressed,
the machine returns to the initial state of
maintenance mode.