STORAGE
4. Repeatedly depress the HI/LOW
beam switch rapidly, then, while
doing this,pressandholdtheSET
button until PUSH “S” appears on
the display.
NOTE: It is critical for this procedure
to depress the HI/LOW beam switch
repeatedly before holding down the
SET button.
mmr2009-004-003
5. Release all buttons when gauge dis-
plays PUSH “S” appears.
6. Again, press and hold the SET (S)
button for 2 - 3 seconds.
NOTE: The gauge will display OIL
when the storage procedure is initi-
ated.
7. When gauge displays OIL, release
button and w ait for the lubrication
functiontoend.
mmr2009-004-004
Do not touch anything during engine lu-
brication cycle.
The engine lubrication function takes
approximately 1 minute. During this
time engine RPM will increase slightly
to approximately 1600 RPM a nd the oil
pump will "oil flood" the engine.
At the end of engine lubrication func-
tion, the ECM will stop the engine .
Remove tether cord cap from engine
cut-off switch.
NOTICE
Do not start the engine
during storage period.
______________