EasyManuals Logo

Bryant PREFERRED T6-PRH-A User Manual

Bryant PREFERRED T6-PRH-A
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #75 background imageLoading...
Page #75 background image
75
Variable Speed/Multi-Stage
Equipment Control Module Furnace Air Conditioner
Heat Stage 2 O/B W2 W2
Heat Stage 1 W/W1 W1
Cool Stage 1 Y1 / W2 Y1
Cool Stage 2 Y/Y2 Y/Y2 Y/Y2
Fan G G
24VAC Hot Heating Rh R R
24VAC Hot Cooling Rc
Dry Contact 1 D1
Dry Contact 2 D2 DHUM
24VAC Common C COM C
Humidify HUM
Outdoor Air Temp OAT
Remote Room Sensor RRS
OAT/RRS Com SRTN
Outdoor Sensor *
Humidifier Solenoid
Valve *
Remote Room
Sensor *
A08136
Fig. 31 -- Variable Speed/Multi-- Stage Furnace w/2--Stage Air Conditioner
* Indicates connection may not be required/available.

Table of Contents