Quick Reference Guide QRG
Quick Reference Guide EDV no.: MD.341.01.01
ekr 500 Plus with CLS Pro 600 Issue Date: 31.03.2009 Page: 18/18
5 Optimise gain
Requirements:
- web of material is fed in
- the guiding device has not operated a limit
switch
- basic setup and material setup of the
CLS Pro 600 is carried out
1. Select guiding mode Line /contrast scanning (sensor 3).
Press key Sensor 3.
The LED of the key lights.
2. Press key Automatic.
The controller changes to automatic mode.
The LED of the key lights.
3. Press key SETUP.
The set controller gain is shown graphically (bar display) and as
numerical value on the lower edge of the display.
4. Increase gain by means of the arrow key “right“ until hunting
occurs (the guiding device oscillates).
The display of the gain value rises step-by-step.
Pressing the arrow key longer than 3 seconds increases the
pulse width until the key is released.
We recommend setting the gain to maximum gain if hunting does
not occur.
5. Decrease gain by means of the arrow key “left“ until the hunting
ceases (stable guiding operation).
You can continue to decrease gain if a slower guiding reaction
is desired.
Simultaneously
pressing the two arrow keys will
reset the controller gain setting to “0.5.
6. Press key ENTER.
Adjustment of gain is completed.
The gain setting will be terminated automatically
after a pre-set time-out period initiated after the
last key operation has expired.
Controller gain
(numerical display)
Controller gain
(graphical display)