Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-06-01
© BT Europe AB Service Manual REFLEX RR B/E, RR B/E CC 10- 7
Electric pump motor –1710
Installation instructions for external temperature sensor
Fasten the metallic lacquer and the sensor with masking tape and
allow it to harden.
Remove the masking tape. The temperature sensor should now be
fixed in place and covered entirely by metallic lacquer.
Remove the ferrite block from the old sensor and mount it on the ca-
ble to the new sensor.
Remove the contact from the broken sensor, which is attached to
the motor.
Place the new sensor contact in the old bracket and connect it to the
cables.
Fasten the old contact and its cables using a cable tie so it cannot
damage anything.