T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
38-  6 Service  Manual  REFLEX RR B/E, RR B/E CC © BT Europe AB
Battery charger – 8340
Functional description
Error indication and error messages
When one or more LEDs flash an error has occurred, after which the 
display automatically, or after pressing the # key, shows the error 
codes. Older program versions demand the # key to be pressed once 
per error code.
Code Error messages
E01 Error code has been entered
E02 Entered value is too large
E03 Error in EE-prom
E10 Mains error
E11 Direct voltage error
E12 Interrupted secondary fuse
E13 Safety shutdown
E14 High temperature
E17 Error in EE-prom
E20 Great need of maintenance charging
E21 High counter-voltage, across 2.4 V/cell
E22 Low counter-voltage, across 1.8 V/cell
E23 Overcurrent, more than double the rated current
E25 Too low current, less than 1% of the rated current
E26 Tripped secondary fuse
E30 High temperature, on transformer or choke
E31 High temperature on the diode heatsink
E32 High ambient temperature
E36 Fan fault
E40 Too low current, less than 1% of the rated current
E43 Charged capacity> programmed capacity × recharging 
factor
E44 Long charging time with voltage over 2.37 V/cell
E52 Phase missing on 3 phase charger
E60 Checksum error in EE-prom
E61 Keyboard error. Key pressed > 20 seconds
E62 Communication error with printer
https://www.forkliftpdfmanuals.com/