T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
38-  10 Service Manual  REFLEX  RR B/E, RR B/E CC © BT Europe AB
Battery charger – 8340
Functional description
Charger specific parameters
Mains voltage codes
Other functions
1)
 Only applies to program version 1.19 or later.
Register Function Default 
value
232 Charger’s rated current, A 0
240 Mains voltage code, see separate table 9
213
1)
Extra charging, 0 = no, 1 = yes 1
225
1)
Time for extra charging, hours 56
217
1)
Equalising charge , 0 = no, 1 = yes 0
216
1)
Pause in equalising charge, hours 10
221
1)
Delayed start, seconds 0
226
1)
Delayed charging, hours 0
242 Fan installed, 0 = no, 1 = yes 1
Main 
voltage
Design of the charger
1-phase 3-phase
220 0 8
380 1 9
500 2 10
127 3 11
346 4 12
Register Function Default 
value
233
1)
Automatic hardcopy of statistics, 0 = no, 
1 = yes
0
234
1)
Hardcopy of charging, 0 = no, 1 = yes 0
235
1)
Hardcopy range, hours 5
203
1)
Hardcopy language, dependent on pro-
gram version
0