T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
43- 4 Service Manual REFLEX RR B,E RR B,E CC © BT Europe AB
Truck log system, code lock – 9420
I/O Module
If the truck does not start:
Check there is 48 V on cable 21 measured with a minus on cable 40.
Check that there is a minus on contact X3:9. This activates the TLS
function
In the event of error code 3 (shock sensor activated) and 4 (truck dis-
abled), see chapter “Warning codes without registration” C code
5710 in this manual.
For further information, see Davis Derby information.
43.4 I/O Module
The I/O module is used to communicate with the electronic card [A5].
The module has 2 outputs that can be loaded with a maximum of
100mA, producing an output voltage of 48V. Communication with the I/
O module is via the CAN bus. The inputs are not used.