Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-06-01
© BT Europe AB Service Manual REFLEX RR B/E, RR B/E CC 24- 13
Electronic card – 5710
Parameter setting of all parameters
18 Lift height limitation
level 2
m 0–13,5 13,5 0 = not connected
> 0 = connected
In steps of 0.05. Set greater or equal
to L.h. limitation 1.
19 Forks’ free lift height m 1,0–4,5 2,2
See
table
Top side of fork to floor when inner
guide is at top.
In steps of 0.01
20 Time indication 1–6 6 1 = Ignition time (A)
2 = Total movement time (b)
3 = Drive motor time (c)
4 = Pump motor time (d)
5 = Service time (S)
6= Weight indication, (b) shown dur-
ing 5 seconds.
21 Battery size 1–20 12
See
table
See table
22 Type of Truck 1–5 2 1 = B/E1-3 with support arm brakes
2 = B/E1-3 without support arm
brakes
3 = B/E4-6 with support arm brakes
4 = B/E4-6 without support arm
brakes
5 = B/E7-8
23 Type of Mast 0/1 1 0 = Old mast
1 = With valve in fork yoke
24 Left foot-switch 1/0 0 0 = Activates buzzer
1 = Also cuts drive motor
25 Service interval h 0–2000 100 0 = No service counter
In steps of 50h
26 Cab tilt 0/1 1 0 = B1-8
1 = E1-8
27 Lift priority 0/1 1 0 = Fork lift prioritised
1 = Fork lift not prioritised
28 Indication signal on
output 208
0-4 0 0= Hydraulics
1= Driving
2= Driving in drive wheel direction
3= Driving in fork direction
4= Shock sensor active
Table 7: List of parameters
No. Parameter type Unit Min./max. Std.
value
Comments
https://www.forkliftpdfmanuals.com/