Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-06-01
© BT Europe AB Service Manual REFLEX RR B/E, RR B/E CC 24- 51
Electronic card – 5710
Warning codes with registration
Hydraulic valve Y14 engages fork tilt down
1. Disconnect the cable 92 from output 704.
- Check that the connector pins make contact, no play and no oxi-
disation.
- Check that the cable 92 is intact between terminal 704 and the
terminals in X17 via X14.
- Measure the coil on Y14 between the orange and black cables in
X17 with an ohmmeter. Resistance approx. 90 ohm.
- Check that cable 40 is intact from X17, via X14 to the battery neg-
ative.
2. If the fault remains, replace A5.
Code 54
Description Output 704 short circuit/breakage
Error mode General error
Error cause 1. Faulty wiring/valve Y14
2. Defective electronic card A5
Comments