24- 62 Service Manual REFLEX RR B/E, RR B/E CC © BT Europe AB
Electronic card – 5710
Warning codes with registration
Tilt control, joystick R13
1. Check that R13 is located in its bracket.
- Check that the voltage across R13 (yellow and grey cable) is 7-
7.5 VDC.
- Check that there is no play or oxidisation on the connector pins
on terminal X11.
- The voltage on input 505 should be 3.7 +/-0.6 VDC when R11 is
correctly adjusted.
2. If the correct voltage is on input 505 and the fault remains, re-
place the A5 electronic card.
Code 91
Description Potentiometer R13 for tilt gives incorrect voltage
(<0.3 or >7.0 V).
Error mode General error
Error cause 1. Faulty potentiometer/wiring or activated input with-
out connected potentiometer
2. Defective electronic card A5
Comments