Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-06-01
© BT Europe AB Service Manual  REFLEX RR B/E, RR B/E CC 24-  9
Electronic card – 5710
Displaying and programming
Clock
When the clock can be set, the hours will blink in the display, and after 
depressing the travel direction selector, the minutes will blink.
• Use the lift/lowering lever to increase/decrease the value.
• Use the travel direction selector to switch between hours and min-
utes.
Complete programming and store the set value by depressing the red 0 
key. 
NOTE:
Altered truck characteristics.
If you alter truck-specific parameters, truck handling will change.
Do not change any parameters unless you have the necessary skills 
to do so.
Driver parameters 1-7
Do as follows to reprogram the driver parameters if this is permitted: 
• Enter the driver PIN-code and then depress the green I key on the 
keypad so that the electronic card will recieve positive feed, at the 
same time push the travel direction selector in the fork direction. 
• Release the travel direction selector when “P” is displayed. The driv-
er number will be shown in the display (E).
• Use the lift/lowering lever to scroll to the parameter to be changed.
• Depress the travel direction selector (the parameter number blinks).
• Use the lift/lowering lever to increase/decrease the value.
• Depress the travel direction selector to confirm the value. (The pa-
rameter number stops blinking.)
To change other parameters, scroll to the desired parameter with the 
lift/lowering lever and then repeat the operation “Depress switch I (the 
parameter number blinks)”.
Complete programming and store the set value by depressing the red 0 
key.
Common driver parameters can only be reprogrammed using a service 
instrument.
Function Value
hours 09 = 9h
minutes 35 = 35 min