T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
24- 20 Service Manual REFLEX RR B/E, RR B/E CC © BT Europe AB
Electronic card – 5710
Parameter setting of all parameters
24.5.21 Parameter 28
Using this parameter, it is possible to switch the information on output
208 during truck operation. Use an intermediary relay if the connected
component draws much current.
24.5.22 Parameter 29
If the truck is equipped with height measurement, use this parameter to
set the maximum lift height. Bypassing this lift height is not possible.
For more information, see parameters 17 and 18.
24.5.23 Parameter 30
Using this parameter, it is possible to switch the information on the I/O
box outputs during truck operation. Use an intermediary relay if the
connected component is draws much current.
24.5.24 Parameter 37
Set this parameter to the weight with which the truck is calibrated.
Complete programming in the usual manner.