Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-06-01
© BT Europe AB Service Manual REFLEX RR B/E, RR B/E CC 38- 7
Battery charger – 8340
Functional description
Reading statistics from the previous charge
The statistics remain in the system until a new charging process is
started or the battery is replaced. The statistics are stored in a register
with a three-digit number in the range 290–500. The most important are
shown in the following table.
Press * register number *.
E63 Error in EE-prom
E67 Battery acknowledgement error
E70 Data in the mother board’s EE-prom is not valid
E72 Error in the mother board’s EE-prom
E76 Error in EE-prom
E77 The content in the computer board’s and the mother
board’s EE-prom is not the same.
Register Function (resolution, unit)
290 Voltage before start, 10 mV/cell.
291 Start current, % of the charger’s rated current.
320 Final voltage, 10 mV/cell.
321 Final current, % of the charger’s rated current.
340 Calculated withdrawn capacity, Ah
360 Total recharged capacity, non maintenance charge,
including recharging factor, Ah