Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-06-01
© BT Europe AB Service Manual REFLEX RR B/E, RR B/E CC 39- 11
Control/computer equipment – 8700
Function for diagnostics
39.9.2 Tab for “Analogue”
When you click on the Analogue tab, the following dialog box is dis-
played:
• Read status – Shows that the measurement function is activated
and functioning.
• Inputs - the measured voltage on each potentiometer is displayed.
The number refers to the input on the main card and which is speci
-
fied on the circuit diagram.
• Outputs - the voltage sent out to each component. The number re-
fers to the output on the main card and which is specified on the cir-
cuit diagram.
• Driver controller - Cmd shows the required Ac-figure and the actual
speed for each engine.