EasyManua.ls Logo

BT REFLEX RR E7-8 - 39.9.2 Tab for “Analogue”

BT REFLEX RR E7-8
514 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-06-01
© BT Europe AB Service Manual REFLEX RR B/E, RR B/E CC 39- 11
Control/computer equipment – 8700
Function for diagnostics
39.9.2 Tab for “Analogue”
When you click on the Analogue tab, the following dialog box is dis-
played:
Read status – Shows that the measurement function is activated
and functioning.
Inputs - the measured voltage on each potentiometer is displayed.
The number refers to the input on the main card and which is speci
-
fied on the circuit diagram.
Outputs - the voltage sent out to each component. The number re-
fers to the output on the main card and which is specified on the cir-
cuit diagram.
Driver controller - Cmd shows the required Ac-figure and the actual
speed for each engine.