T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
41- 16 Service Manual REFLEX RR B,E RR B,E CC © BT Europe AB
Positioning equipment – 9390
Programming parameters
41.12 Programming parameters
Parameter
number
Max./min.
value
Factory
setting
Unit Function
P1 001
002
001 m - 10 mminch -
10ths of an inch
Unit of measurement
P2 1 - 99
0 - 999
0 - 255
0 - 999
st
10 mm
10 mm
10 mm
Programming of several levels at
equal collect/leave distances.
Number of levels
Distance first “collect height”
Distance collect-leave
Distance between “leave levels”
P3 0 - 127
0 - 127
030
010
% of max speed Crawling speed before stop
Lower
Lift
P4 010
005
mm Crawling distance before stop
Lower
Lift
P5 0 - 255 010 mm Permitted error tolerance in stop
position
P7 0 - 255
0 - 255
030
150
mm Min./max. distance between
leave - collect
P8 Resetting of all parameters to
factory settings
P9
0 - 255
0 - 255
050
030
10 mm
10 mm
Braking distance before stop
Lower
Lift