Electronic card – 5710
Error Codes
Main contactor, K10, contactor points
1. Check the voltage on terminal 808. It must be nominal battery
plus, i.e. + 48 VDC, when the truck is stated.
- If there is no voltage, check fuse F62 (10 A).
- If the fuse has not blown, check that cable 23 is intact.
- If cable 23 is okay, check the contactor points on K10.
- If the contactor points are okay, check that cable 1 is okay.
2. If there is a voltage of +48 VDC on the card's terminal 808 and
the fault remains, replace the A5 card.
Code 107
Description The main contactor K10 does not close during truck
start-up and the emergency stop switch does not
operate
Error mode Critical error
Error cause 1. Defective contactor K10
2. Defective electronic card A5
Comments