Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-06-01
© BT Europe AB Service Manual REFLEX RR B/E, RR B/E CC 24- 71
Electronic card – 5710
Error Codes
1. Check the voltage in cable 24. It must be 0 VDC when the red
pushbutton on the keypad is depressed.
If the voltage is correct, disconnect cable 24. If the voltage is still cor-
rect, then replace the A16 keypad.
Code 109
Description Keypad relay does not open.
Error type Travel speed reduced to inching speed
Error causes 1. Short-circuited cable
2. Defective keypad
Note
24
X30
S21
EMERGENCY SWITCH OFF
X30
22
24
21
809
39
45
46
47
48
49
43
805
807
110
111
104
105
107
203
106
+48VDC
INP. KEY
INP. LEFT FOOT SWITCH
+48VDC SUPPLY OUTPUTS
INP. DRIVE. CHANGE DIR
INP. DRIVE, FORKS DIR, CREEP.
INP. DRIVE, STEER WHEEL DIR, CREEP
INP. DRIVE, FORK DIR
INP. DRIVE, STEER WHEEL DIR
INP. SEAT SWITC
ELECTRONIC CARD
A5
https://www.forkliftpdfmanuals.com/