Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-09-09
© BT Europe AB Service Manual REFLEX RR B,E RR B,E CC 5- 3
Preventive maintenance – P2
Maintenance Schedule
4100 Steering console
4100.1 Check the mounting and locking of the
control console
U X
4100.2 Check the strength and locking of the
gas damper
U X
5000 Electrical Panel
5000.1 Clean and check the mountings X
5000.2 Tighten cable connections X
5000.3 Check the emergency driving functions X
5000.4 Check error code log and operation
times
U X
5190.1 Check contactor points X
5190.2 Check movement in the contactor X
5280.1 Check electrical limiting functions X
5110 Battery
5110.1 Check electrolyte levels (10-15 mm over
cell plates)
U X
5110.2 Check connections on the battery, truck
and charger
U X
5110.3 Check the cell and pole guards U X
5110.4 Check fluid density U X
5110.5 Check temperature X
5110.6 Remove overflow fluid from the battery
trough
X
5110.7 Check for wear to the locking catch U X
Table 4: Maintenance schedule RR B/E 1-8
Pos.
no.
Work to carry out
Interval in hours 5 20 250 500 1000 3000
Interval in days/weeks/months 1 d 1
wk
3 m 6 m 12 m 36 m
https://www.forkliftpdfmanuals.com/