Installation and Connections
SM-DIN/MULTILOOP.. - 2.5 -
b) The display of just numbered device shows the assigned number.
c) the DF field on the Board display increases by 1.
Repeat the above procedure for all connected DIAPER FEEDER devices
3 sec to confirm and go back to BOARD SETUP menu
HTP SENSOR IDENTIFICATION
Enter the BOARD SETUP menu.
Select HTP SENS IDENTIFY.
To set the spool change sensor type according to Matrix Cube Type
between CUBE/CUBE 2-3/DISABLED.
3 sec to confirm and go to next parameter
The green LED starts flashing on all the HTP or SE/HTP sensors
Skim the touch light of the first sensor and check the LED changes:
▪ from flashing green to red (for HTP sensors)
▪ from flashing green to flashing red/green (for SE/HTP sensors).
Skim the touch light of the second HTP or SE/HTP sensor and continue with the
numbering of all sensors