EasyManua.ls Logo

Buderus Logamax plus GB162-100 kW - Gas Valve Replacement Procedures; Shut Down the Boiler

Buderus Logamax plus GB162-100 kW
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Contents
Logamax plus GB162- 80/100 kW - Subject to modifications resulting from technical improvements!
5
11.10 Check the air/flue gas connection . . . . . . . . . . . 53
12 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
12.1 Prepare the heating system for maintenance . . 54
12.2 Remove the boiler door . . . . . . . . . . . . . . . . . . . . 54
12.3 Clean the heat exchanger, burner and
condensate trap . . . . . . . . . . . . . . . . . . . . . . . . . .54
12.3.1 Remove the gas valve . . . . . . . . . . . . . . . . . . . . . 54
12.3.2 Remove the burner cover with the fan and the
gas valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
12.3.3 Remove the burner and the burner seal . . . . . . 55
12.3.4 Checking ignition unit . . . . . . . . . . . . . . . . . . . . . 56
12.3.5 Disconnect the condensate trap . . . . . . . . . . . . 56
12.3.6 Remove the condensate collector . . . . . . . . . . . 57
12.3.7 Clean the heat exchanger . . . . . . . . . . . . . . . . . . 58
12.4 Check and adjust the gas/air ratio
(flue gases CO2 emissions) . . . . . . . . . . . . . . . .58
12.5 Function check . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
13 Display information . . . . . . . . . . . . . . . . . . . . . . . . . . 59
13.1 Removing the control panel . . . . . . . . . . . . . . . . 59
13.2 Replacing the control panel . . . . . . . . . . . . . . . . 59
13.3 BC10 Display readings . . . . . . . . . . . . . . . . . . . . 59
13.4 BC10 Display settings . . . . . . . . . . . . . . . . . . . . 60
13.5 BC10 Display codes . . . . . . . . . . . . . . . . . . . . . . 60
14 Technical specifications . . . . . . . . . . . . . . . . . . . . . . . 67
14.1 Technical specifications of GB162-boilers
at sea level (0-4,000 ft.) . . . . . . . . . . . . . . . . . . . .67
15 Reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
15.1 Start-up report . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
15.2 Inspection report . . . . . . . . . . . . . . . . . . . . . . . . . 70
15.3 Service report . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
16 Spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

Table of Contents

Other manuals for Buderus Logamax plus GB162-100 kW

Related product manuals