47
Shutdown
Type 8710, 8711, 8713, 8715
11. SHUTDOWN
11.1. Safety instructions
danger
Danger due to high pressure in the installation.
• Stop the circulation of fluid, cut off the pressure and drain the
pipe before loosening the process connections.
Danger from the outflow of operating fluid.
• Respect the prevailing regulations on accident prevention and
safety relating to the operating fluids used.
Danger due to electrical voltage.
• Shut down and isolate the electrical power source before
carrying out work on the system.
• Observe all applicable accident protection and safety
regulations for electrical equipment.
Warning
Risk of injury from nonconforming dismounting.
• Maintenance must only be carried out by qualified and skilled
staff with the appropriate tools.
11.2. Dismounting of the MFM / MFC
Procedure:
B
A
C
→ Relieve the operating medium pressure in the system.
→ Clean the device using a neutral fluid (nitrogen, for example).
→ Relieve the rinsing medium pressure in the system.
→ Switch off the power supply [A].
→ Disconnect the electrical connections [B].
→ Disconnect the fluid connections [C].
→ Remove the MFM / MFC.
English