EasyManuals Logo

Burnham V9A Series User Manual

Burnham V9A Series
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #51 background imageLoading...
Page #51 background image
51
I. OXYGEN CORROSION:
Oxygen contamination of the boiler water will cause
corrosion of iron and steel boiler components,
and can lead to boiler failure. Burnham’s standard
warranty does not cover problems caused by oxygen
contamination of boiler water or scale (lime) build-up
caused by frequent addition of water.
La contamination par l’oxygène de l’eau de la
chaudière entraînera la corrosion des composants
de la chaudière en fer et en acier et peut entraîner
une panne de la chaudière. La garantie standard de
Burnham ne couvre pas les problèmes causés par la
contamination par l’oxygène de l’eau de la chaudière
ou par l’accumulation de tartre (calcaire) causée par
l’addition fréquente d’eau.
There are many possible causes of oxygen
contamination such as:
a. Addition of excessive make-up water as a result
of system leaks.
b. Absorption through open tanks and ttings.
c. Oxygen permeable materials in the distribution
system.
In order to insure long product life, oxygen sources
must be eliminated. This can be accomplished by
taking the following measures:
a. Repairing system leaks to eliminate the need for
addition of make-up water.
b. Eliminating open tanks from the system.
c. Eliminating and/or repairing ttings which allow
oxygen absorption.
d. Use of non-permeable materials in the
distribution system.
e. Consult your local water treatment specialist for
specic recommendations.
Recommended Water Quality Requirements
pH - 8.3 - 10.5
TDS - 3500 ppm (Max)
Total alkalinity ppm as CaCO
3
- 1200 (Max)
Total copper ppm - .05
Oily matter ppm -1
total harness ppm -3
chlorides - < 50 ppm

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Burnham V9A Series and is the answer not in the manual?

Burnham V9A Series Specifications

General IconGeneral
BrandBurnham
ModelV9A Series
CategoryBoiler
LanguageEnglish

Related product manuals