theboilermustbewithinthe80÷85°С
range.
•It is not recommended to operate the
boiler for a long period of me at an
outputlowerthan50%.
•When using circulaon pump, boiler
operaon must be controlled via a
separatethermostatinordertoensure
theprescribedratedtemperatureofthe
returnwater.
•Theeco-friendlyoperaonoftheboiler
isrealizedatratedoutput.
Table 6. TROUBLE-SHOOTING TABLE
Installaon damage
Cause Soluon
1. Duetounsealedconnecons
1. Install the connecng piping strain-free to
the boiler connecons. Connect the heang
installaon outlet to connecon B. Connect
the heang installaon inlet to connecon A.
MountthecockYincludedinthesetitem. 12.3.
atthedrainageoutlet
2. Due to accumulaon of deposits.
Condensate and tar formaon may
reduce the performance and life of the
heang boiler. The temperature at the
boiler inletmust not be lessthan 65°C,
boiler water temperature at the outlet
mustbebetween 80 and 85°
2. It is mandatory to install a three-way
thermostac valve which will prevent the
temperaturedroppingunder 65°Cattheinlet.
- In order to increase the operaonal life of
theboileritisrecommendedtoinstallabuer
vesselwithcapacityof 55 l per 1 kWofinstalled
power
3. Duetofreezing
3. Iftheheanginstallaon,includingthepiping
network, has not been built frost-proof, we
recommendthatyoulltheheanginstallaon
withaliquidwhichhaslowfreezingpointand
corrosionproteconandanfreezeagent
Output is too low
Cause Soluon
1. Insucientdraught
1. Check chimney condion and measure
draught.(mustbeperformedbyanauthorized
service)
2. Heangvalueofthefuelistoolow.
2. Makesureyouusesucientlydryfuel. When
usingfuelwithhighmoisturecontent,aerthe
reloadingtheboilermayburnforsomemeat
signicantlyloweroutputlevelunlthefuelin
thecombusonchamberhasdried.
3. Presenceofsootdepositsand/ortar
ontheuedamperintheupperchamber
whichpreventitsghtclosure.
3. Clean the ue damper and make sure that
when moving its closing/opening lever it
providesadequatesealingoftheuegasoutlet
intheupperchamber.(mustbeperformedby
anauthorizedservice)
•Itisrecommendedtoinstallastorage/
buer tank and pump type group with
thermostacmixingvalvetotheboiler.
Thecapacityofthestoragetankis55L
ofwaterper1kWinstalledboilerpower.
•Maintenanceandoperaontrainingfor
theboilerisconductedbyanauthorized
installer.
*
Failuretoobservetheinstallaon
and operang requirements
described in the manual and the
servicebookletvoidsthewarranty.