10. CONTROLLER
ThePyroBurnLambdaboilerisequipped
withahi-techreliablecontrollercapableof
managing complex heang installaons.
Combusonprocessismanagedthrough
permanentmonitoringofoxygenlevelsin
exhaustgases, theirtemperatureaswell
astheboilertemperature.Dependingon
those values becomes adjusted the air
intake into the primary and secondary
combuson chamber. The control unit
hasembeddedinitslogicthecapacityof
managingthreeprincipaltypesofheang
installaons.
Thanks to the integrated lambda sensor
the combuson process is opmized
to such an extent that boiler eciency
exceeds 92%,andexhaustgas emissions
conformtostrictestEUstandards.
*
ATTENTION! HIGH VOLTAGE!
Make sure the regulator is
disconnected from the mains
before working on the power
supply (cable connecons, device
installaon, etc.)!
*
All connecon works must only
be carried out by qualied
electricians.
*
The regulator may not be operated
in a closed-circuit central heang
system.
*
Before acvang the controller,
measure the motor reseng
eciency, check the boiler and
inspect wire insulaon. During
assembly, the device must be
disconnected (make sure the
power cord is unplugged)!
Improper cable connecons may
damage the regulator!
*
The device may be damaged if
struck by a lightning. Make sure it
is unplugged during the storms.
10.1. Controller`s view. Explanaon of
buonsandindicators.
F1-Ignion.
F2-Notused.
F3-Notused.
F4-Calibraonofthelambdasensor.
Pg↑-Gotopreviouspage.
Pg↓-Gotonextpage.
+,-Usedtoadjust(increase/reducethe
valueofaparameter).
Enter-Conrmvalueofparameter.
Esc-Stepback.
↑-Switchtoaparameterupthepage.
↓-Switchtoaparameterdownthepage.
The menu display of the controller is
composed of 2 main on-screen menus
and5on-screenmenuswithparameters.
Inthetoplecornerofthedisplayscreen
appearsaniconsymboloftherespecve
on-screenmenushowingalwaysinwhich
menuyouare.
*
Important: changing parameters
inboilersengsispermiedtobe
performedonlybyanauthorized
installer. Entering wrong values
foranyoftheparametersbythe
usermayhavenegaveimpacton
theboilerperformance.