TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
10. CONTROLLER
ThePyroBurnLambdaboilerisequipped
withahi-techreliablecontrollercapableof
managing complex heang installaons.
Combusonprocessismanagedthrough
permanentmonitoringofoxygenlevelsin
exhaustgases, theirtemperatureaswell
astheboilertemperature.Dependingon
those values becomes adjusted the air
intake into the primary and secondary
combuson chamber. The control unit
hasembeddedinitslogicthecapacityof
managingthreeprincipaltypesofheang
installaons.
Thanks to the integrated lambda sensor
the combuson process is opmized
to such an extent that boiler eciency
exceeds 92%,andexhaustgas emissions
conformtostrictestEUstandards.
*
ATTENTION! HIGH VOLTAGE!
Make sure the regulator is
disconnected from the mains
before working on the power
supply (cable connecons, device
installaon, etc.)!
*
All connecon works must only
be carried out by qualied
electricians.
*
The regulator may not be operated
in a closed-circuit central heang
system.
*
Before acvang the controller,
measure the motor reseng
eciency, check the boiler and
inspect wire insulaon. During
assembly, the device must be
disconnected (make sure the
power cord is unplugged)!
Improper cable connecons may
damage the regulator!
*
The device may be damaged if
struck by a lightning. Make sure it
is unplugged during the storms.
10.1. Controller`s view. Explanaon of
buonsandindicators.
F1-Ignion.
F2-Notused.
F3-Notused.
F4-Calibraonofthelambdasensor.
Pg↑-Gotopreviouspage.
Pg↓-Gotonextpage.
+,-Usedtoadjust(increase/reducethe
valueofaparameter).
Enter-Conrmvalueofparameter.
Esc-Stepback.
-Switchtoaparameterupthepage.
-Switchtoaparameterdownthepage.
The menu display of the controller is
composed of 2 main on-screen menus
and5on-screenmenuswithparameters.
Inthetoplecornerofthedisplayscreen
appearsaniconsymboloftherespecve
on-screenmenushowingalwaysinwhich
menuyouare.
*
Important: changing parameters
inboilersengsispermiedtobe
performedonlybyanauthorized
installer. Entering wrong values
foranyoftheparametersbythe
usermayhavenegaveimpacton
theboilerperformance.