24
Parameters in main on-screen menus.
1. Alarm number - Displays a possible
error occurred during boiler operaon.
The error message goes o once the
respecve parameter that evoked the
errormessagereturnstoitslimits.
2. Working Mode - Indicates the actual
operaonmodeoftheboiler.
2.1Modesofoperaon:
2.1.1 OFF -theboilerisinstandbymode,.
2.1.2 IGNITION - The boiler is in ring-
upmode.Thecontrollerfollowsthe„O2
VALUE ON IGNITION“ parameter value
andonceitdropsbelowthepresetvalue,
itshisinto„BurnOn“mode.
2.1.3 Burn On - The boiler is in ignion
mode. The controller monitors the
temperature and oxygen content of
exhaust gases, and depending on the
valuesenteredshisintonormalworking
mode.
2.1.4 Work - The boiler is in normal
operangmode.Thecontrollermonitors
thetemperatureofcoolantinboilerand
the exhaust gases. It also monitors the
oxygenlevelofexhaustgasesandcontrols
the primary and secondary air intake
aps.
2.1.5 Burn Out - The boiler has entered
exncon mode. The boiler goes into
this mode upon exhauson of fuel and
increase of oxygen level in the exhaust
gasesabovethepresetlimitvalue.
2.1.6 Glow - This is the process of
sustainingtheglowbedinsidetheboiler.
Thecontrollerswitchestothismodewhen
exhaustgastemperaturedecreases.
3. BOILER TEMPERATURE - Displays the
temperature inside the boiler water
jacket.
4. EXHAUST TEMPERATURE - Shows the
temperature of exhaust gasesinside the
chimney.
5. O2 VALUE-Displaystheactualvalueof
oxygencontentinexhaustgases.
6. BOILERDOOR - Indicates whether the
boilerdoorisopenornot(open/close).
VALVE PRIMARY - Shows in percentage
howwideisopentheprimaryairap.
VALVE SECUONDARY - Shows in
percentage how wide is open the
secondaryairap.
EXHAUST FAN–Showsinpercentagethe
performancerateofthesuconfan.
BUFFER TOP - Displays the temperature
at the top part of the buer tank. (This
parameter is acve only when the
selected system layout includes a buer
tank.)
BUFFER BOTTOM-Monitorsanddisplays
the temperature at the boom of the
buertank.(Thisparameterisacveonly
whentheselectedsystemlayoutincludes
abuertank.)
WATER HEATER - Monitors and displays
the temperature inside the domesc
hotwatertank.(Thisparameterisacve
when selected system layout includes
domeschotwatertank.)
Explanaonofon-screenparameter
menus