TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
$
DANGER of intoxicaon or
explosion
Toxic gases may be discharged
when burning waste, plascs,
liquids.
- Use only the fuels indicated in
this manual.
- In case of danger of explosion,
ignion or discharge of exhaust
gases in the room, stop the
heang boiler from operaon.
*
CAUTION! Danger of injury /
damage of installaon due to
incompetentoperaon.
- The heang boiler must be
serviced only by persons familiar
with the operaon manual.
- As a user, you are only allowed
to start the boiler up, adjust the
temperature of the boiler, shut
the boiler down and clean it.
- Unaended children must not be
allowed to access a room housing
a running boiler.
Safetyrulesforuseroperaon:
-Operatetheheangboileratamaximum
temperature of 85°C, and to that end
you must regularly inspect the boiler
room.
-Do not use ammable liquids to ignite
thereorincreaseboilersoutput.
-Collecttheashinare-proofcontainer
withalid.
-Clean the heang boiler surface using
non-ammableagentsonly.
-Donotplaceammableobjectsontothe
heang boiler or in its proximity. (see
diagram1fortheminimumclearances)
-Donotstoreammablematerialsinthe
boilerroom.
1.2.3. Minimum clearances for
installaon and combusbility of
building materials
The applicable minimum clearances in
your country may dier from the ones
specied bellow. Please, consult your
installer.
The minimum distance fromthe heang
boiler or exhaust gas pipe to objects or
wallsmustbeatleast200mm.
Diagram 1
Recommended clearances between the
boiler and walls.
For general safety consideraons, we
recommendthattheboilerbeplacedon
afoundaonwithheightof100mmmade
ofclassAmaterial,seetable1.
Table 1
Combusbility of building materials
Class
Аnon-
combusble
Stone, bricks, ceramic les,
baked clay, soluons, plaster
freeoforganicaddives.
Class
Bhard
combusble
Gypsum board panels, basalt
ber needled felt, berglass
board, AKUMIN, Izomin,
Rajolit,Lignos,Velox,Heraklit.
Class С1/С2
Medium
combusble
Woodbeech,oak
Woodsowood,layeredwood
Class
C3easy
combusble
Asphalt, cardboard, cellulose,
tar, berboard, cork,
polyurethane,polyethylene.