Troubleshooting | 11
0870231979_WT0100-0730CP_CV_-0001_IM_en 27 / 36
Abnormal sounds or vibra-
tions.
STOP THE MACHINE
IMMEDIATELY!
The pulleys are placed incor-
rectly. Either parallel-dis-
placed or angle-displaced.
Place the pulleys cor-
rectly.
Damaged bearings. Begin repair with bearing
replacement.
Shortage of oil or dazed oil. Top up or change oil.
Too much oil in oil box. Drain the oil and regulate
the oil level.
Too unstable foundation. Ensure stable foundation.
Resonance in pipe system. Pipe system must be con-
nected to blower with
flexible connections and
supported if necessary.
Too high differential pres-
sure.
Look for causes of in-
creased differential pres-
sure, e.g. blockage or
damage. Check also for
control system-based
causes. Repair.
Air leakage. Find the leakage spots
and repair.
The lobes touch the cylinder
or the end covers.
Begin repair in workshop.
There are foreign bodies in
the cylinder.
Begin repair in workshop.
Damaged check valve Replace check valve.