EasyManua.ls Logo

BUSCH TYR - Page 29

BUSCH TYR
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting | 11
0870231979_WT0100-0730CP_CV_-0001_IM_en 29 / 36
Loss of capacity. Leak in the system. Find the leaks and stop
them.
Activated safety valve. Check differential pres-
sure and see causes
marked with *.
Possibly set the safety
valve’s opening pressure.
Dirty inlet filter or blocked
pipes.
Clean and possibly re-
place filters and pipes.
Loose V-belts. Replace V-belts.
Too high differential pres-
sure*.
See symptoms and causes
marked with *.
Continuously activated
safety valve.
Too high rpm and thereby
too high amount of air (con-
cerns frequency-controlled
blowers).
Lower the rpm.
Too high differential pres-
sure*
Find the cause of the in-
creased differential pres-
sure and repair it.
The valve setting is below
the actual operating point.
Adjust the max limits of
fthe valve within the
blower. Monitor the ab-
sorbed power and ensure
that the setting does not
allow overloading of the
pump.
Abnormally high differential
pressure*
STOP THE MACHINE IM-
MEDIATELY !
Safety valves do not open
despite too high differential
pressure.
Dismantle and clean valve
and possibly readjust.
Blockages on inlet side or
outlet side of the blower.
Clean the pipe system
and look for mechanical
or control system related
blockages or obstructions
that can lead to increased
loss of pressure.
Fault on check valve. Replace check valve.