INSTRUCTION, USE AND
MAINTENANCE MANUAL
Page 35 of 61
EN
Press button to select such procedure and bring
automatically the wheel into weight fitting position.
Fig. 33
1
2 3 4 56
KEY
1 – Only weight to be fitted
2 – Last program and last values used for the spin
3 – Residual dynamic unbalance value (if the value
is yellow, it is not recommended to carry out
ECO-WEIGHT procedure)
4 – Static unbalance value (if the value is yellow,
it is not recommended to carry out ECO-
WEIGHT procedure)
5 – Residual dynamic unbalance value (if the value
is yellow, it is not recommended to carry out
ECO-WEIGHT procedure)
6 – Arrows indicating the weight fitting point with
distance-diameter caliper arm
Press the brake pedal and fit the adhesive weight inside
pliers as shown in Fig. 34.
Fig. 34
Fit the adhesive weight
in the pliers of the gauge rod
Pull out the gauge rod until the arrows (Fig. 33 ref. 6)
turn green.
Fig. 35
Fit weight on the position
where pliers touches the wheel
At the end of the procedure, the wheel balancing condi-
tions can be checked by performing a trial spin.
The ECO-WEIGHT procedure has now been completed.
LIBRAK350 - LIBRAK350PRO