Butler LIBRAK350 - Chuck 0 (Zero) Calibration; Weight Measurement Sensors Calibration

Butler LIBRAK350
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 50 of 61
INSTRUCTION, USE AND
MAINTENANCE MANUAL
EN
14.3.1 Chuck “0” (zero) calibration
Press the button (Fig. 44 ref. 1) to display the
following screen page on the monitor:
After making sure that the chuck is unloaded (no wheel
or mounted accessories), press the button and
close the guard. The chuck will rotate for a few minutes
until you see the screen below:
At this point the machine has all its measuring fields.
Press button
to return to calibrations screen
page.
14.3.2 Weight measurement sensors calibra-
tion
THE NUMERICAL VALUES SHOWN
IN THE FIGURES BELOW ARE
PURELY ILLUSTRATIVE.
ASSEMBLE A BALANCED WHEEL
ON THE SPINDLE AND PERFORM
THE CHUCK “0” (ZERO) CALIBRA-
TION PROCEDURE DESCRIBED
IN PAR. 14.3.1 (WITH WHEEL
MOUNTED).
- Press the button (Fig. 44 ref. 2) to display
the following screen page on the monitor:
- Set the size of the rim on the chuck using the dis-
tance-diameter caliper arm.
- Set the rim width using one of the following calipers:
• Manual caliper
• External data gauge (optional)
- Press button and close the guard to the per-
form the 1st spin of the wheel without weights.
- At the end, on the monitor will appear the following
screen, saying that you should apply a weight of 100
g (3.52 oz) to the “12 o'clock” outer rim.
1296-M024-01
LIBRAK350 - LIBRAK350PRO