Code Reasons Solutions
CHARGE
CURRENT LOW
164
Current driver cannot
provide the requested
charge current
See code 160, Bad fuses or
driver.
CHARGE
CURRENT
REDUCED
118
Battery voltage exceeds
maximum limit (1.8V/cell for
NiMH and NiMH, 2.75V/cell
for SLA). Analyzer will
attempt to complete service
by reducing current rate to
half.
Wait until processing is
complete. If voltage rises
again, code 128 (Soft battery)
appears and the program
ends.
Reduce the charge rate in the
extended C-code.
If the battery is new or has
been in storage, use the
Prime program.
CHARGE CYCLE
COMPLETE
30
Charge cycle completed. Program is going to the next
step.
CHARGE
TIMEOUT
144
Charge time has exceeded
the expected value for the
battery.
Verify that the mAh rating of
the battery matches the C-
code mAh setting.
Analyzer may not have
detected the end of charge
conditions. Reduce the
negative slope to 8mV/cell for
NiCd and NiMH. Raise the
End of Charge settings for Li-
ion, Li-Ph or SLA.
CHARGE WAIT 9
Station is on hold until
sufficient power is available.
This is normal if large
batteries are being serviced.
Service resumes
automatically when sufficient
power is available to the
station.
CHARGING 2
Battery is being charged
normally.