Code Reasons Solutions
UNABLE TO
CLAMP CHARGE
VOLTAGE
128
Battery voltage is too high:
NiCd and NiMH - more than
1.8V/cell
SLA – more than 2.75V/cell.
Li-ion – more than 4.5V/cell
Li-Ph – more than 3.85V/cell
Processing has ended.
Battery may be a high
capacity type battery. Reduce
the charge rate.
Battery may be overcharged.
Discharge the battery for 10
minutes, and then charge
again.
Battery is new. Use the Prime
program to prepare the
battery for use.
Raise End of Charge (SLA, Li-
ion ad Li-Ph) to 0.10C.
Check that correct contacts
are used.
UNABLE TO
LEARN MATRIX
179
A matrix cannot be created
because: battery capacity is
less than 50%, the OhmTest
reading does not produce a
result or the battery cannot
handle 1.00C charge or
discharge rate required by
Learn
Use another battery to run Q-
Learn or Learn.
USER
PROGRAMMED
TIMEOUT
33
The time programmed in a
custom program has
completed.
The program goes to the next
step.
147