EasyManuals Logo

Calculated Industries ElectriCalc Pro Pocket Reference Guide

Calculated Industries ElectriCalc Pro
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #36 background imageLoading...
Page #36 background image
Pocket RefeRence Guide
— 35
(cont’d)
3. Enter number of THWN Wires:

THHN 3.
WIRES
4. Enter second Wire Size:
*
AWG 2 CU
WIRE SIZE
5. Enter number of XHHW Wires:

XHHW 1.
WIRE
6. Find Conduit Size:
FMC 1.50 in
COND SIZE
7. Find total number of Wires:
4.
TTL WIRES
8. Find Conduit Fill Percent:
FILL 36.1
% COND
9. Find actual Fill Area:
FILL 0.6711
TTL WIRE AREA
10. Find Remaining Area:
REM 0.0717
WIRE AREA
CONVERTING KILOWATT-HOUR
AND BTU
Find the equivalent BTU rating of a
3.5 kilowatt-hour rated furnace.
KEYSTROKE DISPLAY

0.
1. Enter kilowatt hours:

3.5
2. Find equivalent BTU:
(Kw-hrBtu)
BTU 11,953.552

Other manuals for Calculated Industries ElectriCalc Pro

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Calculated Industries ElectriCalc Pro and is the answer not in the manual?

Calculated Industries ElectriCalc Pro Specifications

General IconGeneral
TypeScientific
CoverYes
Form factorPocket
Control typeButtons
Product colorYellow
Digits8 digits
Display typeLCD
Display tiltingNo
Display size (HxV)15.88 x 63.5 mm
Display number of lines- lines
Display size (HxV) (imperial)0.625 x 2.5 \
Storage media type-
Battery typeCR2016
Power sourceBattery
Battery voltage3 V
Number of batteries supported1
Weight and Dimensions IconWeight and Dimensions
Depth16 mm
Width76 mm
Height142 mm
Weight127.5 g

Related product manuals