30
MTM NA ‘QUICK’ START INSTRUCTIONS
The following instructions relate to Keypad supplied
from new only and set to Master.
See SW2 selector on rear of keypad for master/
slave selection.
At time of first installation, no entry codes have been
pre-assigned for this purpose, additionally a default
Master/Engineering code 0000 has been is assigned.
If you simply wish to set or change the relay codes;
follow strictly as set out below.
Enter 0000**. The lower light strip on the keypad
turns red to indicate that you have entered the
programming mode.
Enter this sequence: 10 xxxx (new engineering code 4 digits) # **
If you wish to change the pre-assigned engineering code 0000 to your users preferred code, follow
strictly as set out below.
To enter keypad programming once powered up:
To set an entry code associated with user ID 001 for relay 1.
To set an entry code associated with user ID 001 for relay 2.
(999 slots available)
Enter this sequence: 21 2 001* XXXX (new code 4-8 digits) # **
(999 slots available)
Enter this sequence: 22 2 001* XXXX (new code 4-8 digits) # **
To delete all entry codes associated user ID 001 for relay 1.
To delete all entry codes associated user 001 ID for relay 2.
Enter this sequence: 21 5 001# **
Enter this sequence: 22 5 001# **