27 - Manual FA01310-EN - 02/2020 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
Radio decoding
Choose the type of radio coding for the transmitters enabled to control the operator.
If you choose the type of radio coding for the transmitters [Rolling code] or [TW key block], any transmitters with a different type of radio coding saved
previously will be deleted.
U4 Radio decoding 1 = All decoding (default)
2 = Rolling code
3 = TW key block
Motor type
Set the type of gearmotor installed.
A1 Motor type 1 = BX704
2 = BX708
Travel calibration
Start the travel self-learning.
This function appears only if the [Encoder] function is active.
A3 Travel calibration OFF (Default)
ON
Parameter reset
Restore factory settings except for the functions: [Radio decoding], [Motor type] and the settings related to travel calibration.
A4 Parameter reset OFF (Default)
ON
Manoeuvre counter
View the number of operator manoeuvres.
A5 Manoeuvre counter 001 = 100 manoeuvres
010 = 1000 manoeuvres
100 = 10000 manoeuvres
999 = 99900 manoeuvres
CSI = Maintenance work
FW version
Display the firmware version number and the GUI installed.
H1 FW version

Related product manuals