A
B
p. 10 - Manual FA01158 -EN - 02/2023 - © CAME S.p.A. - Translated original instructions
INWARD OPENING CONNECTIONS AND INSTALLING
Fastening the braces
Measure quotas A and B (while respecting the quotas shown on the table) to establish the point where the post brace joined with non-supplied
supplementary brace will be fastened.
Application dimension (mm)
KR300 - KR302 - KR310
Leaf opening arc (°) A B E
90° 130 130 910
KR510 - KR512
Leaf opening arc (°) A B E
90° 200 200 1310
For opening
Release the gearmotor.
Reach the wanted leaf-opening point.
Send a (2-3) opening command and turn the threaded rod clockwise until the microswitch activates to stop the gearmotor.
Leave the nut loose on the threaded rod.
Do the same procedure for the right-side gearmotor.