p. 9 - Manual FA01158 -EN - 02/2023 - © CAME S.p.A. - Translated original instructions
Establishing the limit-switch points
Before establishing the limit-switch points, you must remove the cover by loosening the fastening screw.
For closing
Release the gearmotor.
Push the leaf to its closing strike position.
Send a (2-4) closing command and turn the threaded rod 󱤪 counter clock-wise until the closing microswitch activates to stop the gearmotor.
Leave the nut loose on the threaded rod.
Do the same procedure for the right-side gearmotor.
The closing microswitches 󱤴are positioned at the far ends of their travel range.