6.6- SAFETY DEVICES
“Open during closing” (N.C.) socket
- Input for safety devices such as photocells, sensitive
edges and other EN 12978 compliant devices. When gate
leaves are closing, opening the contact causes reversal
until total opening is obtained.
“Partial stop” (N.C.) socket
- input for safety devices such as photocells, sensitive
edges and other EN 12978-compliant devices. Halts
moving gate leaves and causes them to automatically
close
“Open during closing” (N.C.) socket
“Partial Stop” (N.C.) socket
DIR photocells
DOC photocells
DIR photocells
DOC photocells