Page 11 - Manual FA02007-IT - 11/2023 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
Partial opening or pedestrian opening (contact 2-3P)
By default, the opening is set to pedestrian mode.
To enable in partial opening:
select the DIP-switches as shown and press the PROG button on the control board. The LED stays lit and the
buzzer sounds once.
To return to the default setting, press PROG again. The LED flashes and the buzzer sounds off twice.
Obstruction detection with motor stopped
By default, this function is enabled.
To disable it:
select the DIP-switches as shown and press the PROG button on the control board. The LED flashes and the
buzzer sounds off twice.
To return to the default setting, press PROG again. The LED stays lit and the buzzer sounds once.
Excluding the Encoder
By default, the Encoder is enabled.
To disable it:
select the DIP-switches as shown and press the PROG button on the control board. The LED flashes and the
buzzer sounds of once.
To return to the default setting, press PROG again. The LED stays lit and the buzzer sounds off twice.
Timed slow-downs (with Encoder disabled)
By default, the feature is disabled.
To enable it:
select the DIP-switches as shown and press the PROG button on the control board. The LED stays lit and the
buzzer sounds once.
To return to the default setting, press PROG again. The LED flashes and the buzzer sounds off twice.
Set the APP./O.T. trimmer to maximum and the SENS trimmer to half.
Store the trimmer values according to the procedure indicated.
Automatic closing
By default, the feature is disabled.
To enable it:
select the DIP-switches as shown and press the PROG button on the control board. The LED stays lit and the
buzzer sounds once.
To return to the default setting, press PROG again. The LED flashes and the buzzer sounds off twice.
The wait before the automatic closing starts when the opening limit-switch point is reached - for a time that
is settable on the A.C.T. trimmer.
⚠
The automatic closing does not activate if the safety devices are triggered due to obstacle detection, after
a total stop or if the power supply is missing.
Automatic closing after either partial or pedestrian opening
By default, the feature is disabled.
To enable it:
Select the DIP-switches as shown and press the PROG button on the control board. The PRG LED stays lit
and the buzzer sounds once.
To return to the default setting, press PROG again. The LED flashes and the buzzer sounds off twice.
⚠
The automatic closing time is permanently set to 10 seconds.
Pre-flashing (pre-flashing duration: 5 s)
By default, the feature is disabled.
To enable it:
select the DIP-switches as shown and press the PROG button on the control board. The PRG LED stays lit
and the buzzer sounds once.
To return to the default setting, press PROG again. The LED flashes and the buzzer sounds off twice.
Closing thrust
By default, the feature is disabled.
To enable it:
select the DIP-switches as shown and press the PROG button on the control board. The PRG LED stays lit
and the buzzer sounds once.
To return to the default setting, press PROG again. The LED flashes and the buzzer sounds off twice