Timed slow-downs with Encoder disabled
Set the OP TIME trimmer to maximum, set the SENS
trimmer to half, save the trimmers' values, disable the
Encoder, enable the timed slow-down function.
Start the gate-leaf travel self-learning procedure.
The operator will perform a series of maneuvers to establish
the starting slow-down and limit-switch points.
A = 25% of the working time at slowed opening speed.
B = 25% of the working time at slowed closing speed.
How to change the opening and closing slow-down points with Encoder enabled
Close the gate leaves.
Start the gate-leaf travel self-learning procedure.
When M2 reaches the desired closing slow-down starting
point B (10/45 % of the travel), press the PROG button.
Press again the PROG button when M2 reaches the desired
opening slow-down starting point A (55/90 % of the travel).
Repeat the procedure for M1.
Auto-learning of the gate-leaf travel
With the Encoder enabled (the default setting)
Select the DIPs and press the PROG key on the board as shown in features programming.
The operator will perform a series of maneuvers to establish
the starting slow-down and limit-switch points.
A = 25% of the movement area at slowed down speed
when opening.
B = 25% of the area of movement at slowed down closing speed.
With Encoders and timed slow-downs disabled
If the Encoder and Slow-down functions are both
disabled, the gate leaves will open or close completely at a
constant, limited speed of 50% of the top speed.