6. Strike the nutted end of the concrete stud anchors until a minimum of six threads are below
the surface of the concrete.
7. Finish the installation as if the stud anchors were J-bolts as described previously.
E.4 Pole grounding
Drive the ground rod into the ground next to the cement.
For installations without the pedestal, mount the ground clamp to the mast below the enclosure.
Attach the 4 AWG wire to the ground clamp and the ground rod.
For installations with the pedestal, ground the mast by attaching the 4 AWG wire to the ground
lug on the pedestal and the ground rod. Mount the ground clamp to the mast below the
enclosure. Attach the 4 AWG wire to the ground clamp and the ground rod.