1
1 GENERAL INFORMATION
Camus Hydronics proudly introduces the Modulating MicoFlame series of water heaters / hydronic
boilers. The Modulating MicoFlame is a fan assisted appliance based on a push through design which
offers several venting options. Heat output is controlled by an adjustable ratio air/gas control valve. The
Modulating MicoFlame Models are capable of modulating from 100% down to 35% of rated input. These
gas-burning appliances are thoughtfully designed for easy operation and maintenance. We are confident
that you will come to appreciate the benefits of our product.
The installation of this heater must conform to the requirements of the authority having jurisdiction or, in
the absence of such requirements, to the latest or current as amended National Fuel Gas Code, ANSI
Z223.1 or current CAN/CGA B149 Installation Codes. All electrical wiring must be done in accordance
with the requirements of the authority having jurisdiction or, in the absence of such requirements, with the
National Electrical Code, ANSI/NFPA 70 or the Canadian Electrical Code Part I, CSA C22.1 Electrical
Code.
Vent installations must be in accordance with Part 7, Venting of Equipment, of the latest or current as
amended National Fuel Gas Code, ANSI Z223.1, or Section 7, Venting Systems and Air Supply for
Appliances, of the current CAN/CGA B149, Installation Codes and applicable provisions of the local
building codes.
When required by the authority having jurisdiction, the installation must conform to the Standard for
Controls and Safety Devices for Automatically Fired Boilers, ANSI/ASME CSD-1.
The qualified installer shall instruct the end user in the safe and correct operation of this appliance and
shall ensure that the heater is in safe working order prior to leaving the job site.
WARRANTY:
Factory warranty shall apply only when the boiler is installed in accordance with local plumbing
and building codes, ordinances and regulations, the printed instructions provided with it and
good industry practices.
Excessive water hardness causing a lime build-up in the copper coils or tubes is not a fault of the
boiler and is not covered by warranty. Consult the factory for recommendations for use in hard
water areas.
Using or storing corrosive chemicals in the vicinity of this boiler can rapidly attack the copper
tubes and coils and voids warranty.
The primary heat exchanger of this boiler is intended to operate under non-condensing
conditions. Inlet temperatures must be maintained at 130°
°°
°F or higher. Warranty is void if the
primary heat exchanger is allowed to operate in condensing mode.
Damage caused by freezing or dry firing voids warranty.
This boiler is not to be used for temporary heating of buildings under construction.