Avenger® Series
Installation, Operation and Service Manual
Gas Fired Commercial Condensing Stainless Steel Boilers
Hydronic Heating Models ARH1000 thru ARH4000
Hot Water Heater Models ARW1000 thru ARW4000
WARNING
If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury
or death.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance,
Do not touch any electrical switch; do not use any phone in your building,
Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions,
If you cannot reach your gas supplier, call the fire department.
A Qualified installer, service agency or the gas supplier must perform installation and service.
WARNING
Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.
TO THE INSTALLER: After installation, these instructions must be given to the end user or left on or near the appliance.
TO THE END USER: This booklet contains important information about this appliance. Retain for future reference.
H
HLW

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Camus Hydronics Avenger Series and is the answer not in the manual?

Summary

PART 1 GENERAL INFORMATION

1.2 SPECIAL INSTRUCTIONS TO OWNER

Manual review before installation is recommended for proper understanding of the appliance.

1.4 SEQUENCE OF OPERATION

Details the step-by-step process from power on to burner ignition and operation.

1.9 CLEARANCE FROM COMBUSTIBLE MATERIAL

Specifies minimum safe distances from combustible materials for installation.

1.10 INSTALLATION PROCEDURE AND LOCATION OF UNIT

Guidelines for selecting an appropriate installation location and procedure.

PART 2 VENTING & AIR SUPPLY

2.1 GENERAL VENTING GUIDE

Provides overall guidance for venting the appliance, including material and code compliance.

2.1.4 VENT TERMINATION CLEARANCES

Specifies required clearances for vent terminals from building features and surroundings.

2.2 CONVENTIONAL VENTING (INDOOR) INSTALLATIONS

Details requirements for indoor venting installations using common or dedicated chimneys.

2.4 SIDEWALL VENTING

Covers requirements and guidelines for sidewall venting configurations.

PART 3 GAS CONNECTIONS

3.1 GAS CONNECTION

Outlines requirements for safe and proper gas supply connection to the appliance.

3.4 AIR;GAS RATIO VALVE

Explains the operation and function of the air/gas ratio control valve for combustion.

3.7 CHECKING GAS SUPPLY PRESSURE

Procedure for verifying the incoming gas supply pressure meets specifications.

3.8 CHECKING DIFFERENTIAL AIR AND DIFFERENTIAL GAS PRESSURES

Details how to measure and adjust air and gas differential pressures for proper combustion.

PART 4 WATER CONNECTION

4.1 FREEZE PROTECTION

Provides methods and recommendations for preventing freezing in the appliance and system.

4.10 LOW WATER CUTOFF

Explains the function and installation of the Low Water Cutoff safety device.

4.12 CIRCULATING PUMP SELECTION

Guidance on selecting the appropriate circulating pump for optimal performance.

PART 5 ELECTRICAL & CONTROLS

5.1 ELECTRICAL CONNECTIONS

Details power requirements and wiring instructions for the appliance.

5.3 ELECTRONIC LOW AIR PRESSURE SWITCH (DIFFERENTIAL)

Describes the function of the low air pressure switch for combustion proofing.

5.6 HIGH LIMIT

Explains the high limit Aquastat control for maximum discharge water temperature.

5.9 ERROR TABLE

Lists and explains various error codes displayed by the appliance controller.

PART 6 CONTROL PANEL

6.1 APPLIANCE TEMPERATURE CONTROLLER

Overview of the SOLA controller, its functions and display.

6.2 CONFIGURE MENU

Guides users through the appliance configuration menu for various settings.

6.3 LEAD LAG SETUP

Configuration details for setting up lead lag operation between multiple boilers.

PART 8 FIELD STARTUP PROCEDURES

8.1 CHECKING THE INSTALLATION

Pre-startup checks to ensure correct water, gas, and electrical connections.

8.3 GAS VALVE ADJUSTMENT PROCEDURE

Procedure for adjusting the gas valve for optimal combustion settings.

8.4 COMISSIONING APPLIANCE

Final steps for placing the appliance into service after startup.

PART 10 MAINTENANCE

10.1 EXAMINE THE VENTING SYSTEM

Guidance on inspecting the venting system for tightness, corrosion, and blockages.

10.5 BURNER MAINTENANCE

Instructions for removing, cleaning, and inspecting the appliance burner.

10.13 FREEZE PROTECTION

Recommendations and procedures for protecting the appliance from freezing.

PART 11 INSTALLATIONS

11.1 CHECKING THE INSTALLATION

Final checks before starting the boiler, including gas, water, and electrical connections.

11.3 HEATING BOILER INSTALLATIONS

Recommendations for installing heating boilers, including piping and system requirements.

PART 12 EXPLODED VIEW

AVENGER PARTS LIST

A list of parts with corresponding figures and model applicability.

PART 13 ELECTRICAL DIAGRAMS

CONDENSING BOILER LIMITED WARRANTY

GENERAL

General terms and conditions of the limited warranty for the appliance.

HEAT EXCHANGER

Specific warranty coverage and duration for the heat exchanger component.

HOW TO MAKE A CLAIM

Instructions on how to submit a warranty claim to Camus Hydronics.

Camus Hydronics Avenger Series Specifications

General IconGeneral
Fuel TypeNatural Gas or Propane
ConstructionStainless Steel Heat Exchanger
Thermal EfficiencyUp to 95%
IgnitionElectronic
EfficiencyUp to 95%
Operating Pressure30 psi
Vent Diameter2" or 3"
DimensionsVaries by model
WeightVaries by model