Prevent any outgoing connection to the Internet
Introduction
Some system features allow or request a connection over the Internet to work properly.
When the Security Policy in a company prevents any outgoing network traffic over the Internet,
perform all the following actions, step by step, in Express WebTools:
In the Express WebT‐
ools section
Action Detail
1 Support - Remote
Service - Remote as-
sistance
Stop the Remote assistance if it is
activated
Click 'Stop remote assis-
tance' until it changes into
'Allow remote assistance' .
The two blinking arrows on
the right side disappear.
2 Preferences - System
Defaults - Service rela-
ted information
Disable Online Services or Remote
Service
Set 'Océ Online Services con-
nection enabled' or 'Remote
Service connection' to 'Disa-
bled'
3 Security - Configura-
tion - Permissions for
Service
Disable the automatic update of
the embedded Service information
Set 'Allow automatic update
of embedded Service docu-
mentation' to 'Disabled'
4 Configuration - Exter-
nal location
Delete all External locations going
to the Internet:
• External cloud through WebDAV
protocol
• FTP sites reachable through the
Internet
5 Configuration - Con-
nectivity - Proxy set-
tings
Disable the proxy (recommended
as an additional security measure)
Set 'Proxy enabled' to 'Disa-
bled'
6 Support - About - Shut
down
Restart the system
Prevent any outgoing connection to the Internet
158