Application /Func‐
tionality
System Supported security levels (x)
and open port
Port used on the
controller: pro‐
tocol
N* M* M-H* H*
IPsec Océ PlotWave 750 /
PlotWave 900 R2.x
x
UDP
500
UDP
4500
UDP 500
UDP 4500
Océ Remote Meter
Reading Manager
Océ PlotWave 750 /
PlotWave 900 R2.x
x
UDP
161
UDP 161: SNMP
Océ Remote Service Océ PlotWave 750 /
PlotWave 900 R2.x
x x x x HTTPS outgoing
connection re-
quired: TCP/IP
port 443
(3)
WSD print / WSD dis-
covery
Océ PlotWave 750 x x x UDP 3702
TCP 5357
Notes:
• * Levels: N: Normal - M: Medium - M-H: Medium/High - H: High
•
(**)
The name resolution is mainly used to determine the IP address of the scan destination
during Scan to File operation
•
(1)
FTP active mode only
•
(2)
Data channel for FTP passive mode
•
(3)
TCP/IP port 443 must be opened and must allow response back on the IT infrastructure
firewall.
Applications, protocols and ports used on the Océ PlotWave 750 and the Océ PlotWave 900 R2.x systems