8400-0181-OM Rev C 185 and 185B Installation & Technical
29
EVENT COUNTERS
The Cardinal Model 185 Weight Indicator has been designed with a Category 1 Audit Trail type
of security seal with two event counters. One counter is for calibration parameters and one is
for configuration parameters. Each event counter can log up to 10,000 events. The data is
maintained in non-volatile memory and can be viewed by a Weights and Measures inspector.
The calibration event counter (CAL=) will increase by one when Setup mode is exited after
changing any calibration parameter (for example, fine span adjustment).
The configuration event counter (CFg=) will increase by one when Setup mode is exited after
changing any of the following parameters:
USA
Domestic or International
LFt
Legal For Trade
Unit1
Weighing Units 1
Int
Interval Setting
dPP
Decimal Point Position
CAP
Capacity
Unit2
Weighing Units 2
trA
Zero Tracking Range
trL
± 2% Zero Limit
UnS
Motion Range
SC
Stable Count
FLt
Digital Filter Level
F
Filter Level
Br
Break Range
To Display the Event Counters:
1. With the indicator ON, press the Fn/ key.
2. The display will show Fn=.
3. Press the NET/GROSS key.
4. The display will change to show CAL=.
5. Press the TARE key.
6. The display will change to show the calibration event counter.
7. Press the TARE key.
8. The display will change to show CFg=.
9. Press the TARE key.
10. The display will change to show the configuration event counter.
11. Press the TARE key.
12. The indicator will return to the normal weight display.