Carrier 100 Series - Adjustments

Carrier 100 Series
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table
11—Model
58TUA
Orifice
Size
and
Manifoid
Pressure
for
Correct
Input
Rate
(Tabulated
Data
Based
on
Altitude
Up
to
2000
ft
and
20,000
Btuh
High
Heat/13,000
Btuh
Low
Heat
Per
Burner)
SPECIFIC
GRAVITY
OF
NATURAL
GAS
VjiA5>
MtAT
VALUE
(BTU/CU
FT)
0.58
0.60
0.62
0.64
0.66
0.68
0.70
.
0.72
Orf
No.
Heat
High/Low
Orf
No.
Heat
High/Low
Orf
No.
Heat
High/Low
Orf
No.
Heat
High/Low
Orf
No.
Heat
High/Low
Orf
No.
Heat
High/Low
Orf
No.
Heat
High/Low
Orf
No.
Heat
High/Low
860
43
3.7/1.6
43
3.8/1.6
42
3.2/1,4
42
3.3/1.4
42
3.4/1,5
41
42
3.2/1.4
3.6/1.5
41
42
3.3/1.4
3.7/1.5
41
42
3.4/1.4
3.8/1.6
875
43
3.6/1.5
43
3.7/1.6
43
3.8/1.6
42
3.2/1.4
42
3.3/1.4
42
3.4/1.4
41
42
3.2/1.3
3.5/1.5
41
42
3.3/1.4
3.6/1.5
890
43
3.5/1.5
43
3.6/1.5
43
3.7/1.6
43
3.8/1.6
42
3.2/1.4
42
3.3/1.4
42
3.4/1.4
41
42
3.2/1.3
3.5/1.5
905
43
44
3.3/1.3
3.7/1.5
43
3.5/1.4
43
3.6/1.5
43
3.7/1.5
43
3.8/1.6
42
3.2/1.4
42
3.3/1.4
42
3.4/1.4
920
43
44
3.2/1.3
3.7/1.5
43
44
3.3/1.4
3.8/1.6
43
3.5/1.4
43
3.6/1.5
43
3.7/1.5
43
3.8/1.5
42
3.2/1.3
42
3.3/1.3
935
44
3.6/1.5
43
44
3.2/1.4
3.7/1.6
43
44
3.3/1.4
3.8/1.6
43
3.5/1.5
43
3.6/1.5
43
3.7/1.5
43
3.8/1.6
,
42
3.2/1.3
950
44
3.5/1.5
44
3.6/1.5
43
44
3.2/1.4
3.7/1.6
43
44
3.3/1.4
3.8/1.6
43
3.4/1.5
43
3.6/1.5
43
3.7/1.5
43
3.8/1.6
965
44
3.4/1.4
44
3.5/1.5
44
3.6/1.5
43
44
3.2/1
A
3,7/1.6
43
44
3.3/1.4
3.8/1.6
43
3.4/1.5
43
3.5/1.5
43
3.6/1.5
980
44
3.3/1.4
44
3.4/1.4
44
3.5/1.5
44
3.6/1.5
43
44
3.2/1.4
3.7/1,6
43
44
3.3/1.4
3.8/1.6
43
3.4/1.5
43
3.5/T.5
995
44
45
3.2/1.3
3.8/1.6
44
3.3/1.4
44
3.4/1.4
44
3.5/1.5
44
3.6/1.5
43
44
3.2/1.4
3.7/1.6
43
44
3.3/1.4
3.8/1.6
43
3.4/1.4
1010
45
3.7/1.6
44
45
3.2/1.3
3.8/1.6
44
3.3/1.4
44
3.4/1.4
44
3.5/1.5
44
3.6/1.5
43
44
3.2/1.4
3.7/1.6
43
44
3.3/1.4
3.8/1.6
1025
45
46
3.6/1.5
3.8/1.6
45
3.7/1.6
44
3.2/1.3
44
3.3/1.4
44
3.4/1.4
44
3.5/1.5
44
3.6/1.5
43
44
3.2/1.4
3.7/1.6
1040
45
46
3.5/1.5
3.7/1.6
45
46
3.6/1.5
3.8/1.6
45
3.7/1.6
44
3.2/1.3
44
3.3/1.4
44
3.4/1.4
44
3.5/1.5
44
3.6/1.5
1055
45
46
3.4/1.4
3.6/1.5
45
1
46
3.5/1.5
3.7/1.6
45
46
3.6/1.5
3.8/1.6
45
3.8/1.6
44
3.2/1.3
44
3.3/1.4
44
3.4/1.4
j
44
3.5/1.5
1070
45
46
3.3/1.4
3.5/1.5
45
i
46
:
3.4/1.4
3.6/1.5
45
46
3.5/1.5
3.7/1.6
45
:
46
!
3.7/1.5
3.8/1.6
45
3.8/1.6
44
3.2/1.4
44
3.3/1.4
44
3.4/1.4
1085
45
46
47
3.2/1.4
3.4/1.4
3.8/1.6
45
46
3.3/1.4
3.5/1.5
45
46
3.4/1.5
^
3.6/1.5
45
46
3.6/1.5
3.7/1.6
45
3.7/1.5
45
3.8/1.6
44
3.2/1.4
44
3.3/1.4
1100
46
47
3.3/1.4
3.7/1.6
45
46
3.2/1.4
3.4/1.4
45
46
3.4/1.4
3.5/1.5
45
46
3.5/1.5
3.6/1.5
45
46
3.6/1.5
3.8/1.6
45
3.7/1.6
45
3,8/1.6
44
3.2/1.4
f.
The
gas
valve
and
humidifier
terminal
HUM
are
not
energized
for
safety
reasons.
NOTE:
The
EAC
terminals
are
energized
when
the
blower
is
energized.
2.
P
urge
gas
lines—After
all
connections
have
been
made,
purge
the
lines
and
check
for
leaks.
3.
T
o
operate
furnace,
follow
procedures
on
operating
instruc¬
tions
label
attached
to
furnace.
4.
W
ith
furnace
operating,
set
thermostat
below
room
tempera¬
ture
and
observe
that
furnace
goes
off.
Set
thermostat
above
room
temperature
and
observe
that
furnace
restarts.
ADJUSTMENTS
1.
Set
gas
input
rate.
The
gas
input
rate
must
be
set
for
both
high-fire
and
low-fire.
Each
adjustment
is
independently
made
at
the
gas
control
regulators.
Therfe
are
2
methods
of
adjusting
the
gas
input
rate.
The
preferred
method
is
by
using
Table
11
and
item
a.
The
second
method
is
by
clocking
the
gas
meter
as
outlined
in
item
b.
The
Procedure
in
item
b.
MUST
be
used
for
altitudes
above
2000
ft.
The
gas
valve
regulator
has
been
nominally
set
at
1.5-in.
wc
for
low
fire
and
3.5-in.
wc
for
high
fire
for
natural
gas.
a.
Check
gas
input
rate
using
Table
11.
(1.)
Obtain
average
yearly
heat
value
for
local
gas
supply.
(2.)
Obtain
average
yearly
specific
gravity
for
local
gas
supply;
(3.)
Verify
furnace
model.
Table
11
can
only
be
used
for
Model
58TUA
Furnaces.
(4.)
Check
and
verify
orifice
size
in
furnace.
NEVER
ASSUME
THE
ORIFICE
SIZE.
ALWAYS
CHECK
AND
VERIFY.
(5.)
Find
natural
gas
heat
value
and
specific
gravity
in
Table
11.
(6.)
Follow
heat
value
and
specific
gravity
lines
to
point
of
intersection.
Find
orifice
size
and
manifold
pressure
settings
for
proper
operation
at
given
natural
gas
conditions
on
low
and
high
fire.
15