Carrier 100 Series - Unconfined Space; Type B-1 Double-Wall Vent

Carrier 100 Series
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13/16
11/16
NOTE:
2
ADDITIONAL
7/8
DIA
KNOCKOUTS
ARE
LOCATED
IN
THE
TOP
PLATE
NOTH:
AIR
DELIVERY
ABOVE
1800
CFM
REQUIRES
THAT
BOTH
SIDES
OF
FURNACE
BE
USED,
OR
A
COMBINATION
OF
1
SIDE
AND
BOTTOM,
OR
BOTTOM
ONLY
FOR
RETURN
AIR.
Fig.
1—Dimensional
Drawing
14-1/2
A88367
Table
2—Dimensions
(In.)
UNIT
SIZE
A
D
E
VENT
CONN
SHIP.
WT
040-08
14-3/16
12-9/16
12-11/16
4
122
040-12
14-3/16
12-9/16
12-11/16
4
124
060-08
14-3/16
12-9/16
12-11/16
4
132
060-12
14-3/16
12-9/16
12-11/16
4
134
080-14
17-1/2
15-7/8
16
4
150
080-16
21
19-3/8
19-1/2
4
154
100-12
17-1/2
15-7/8
16
4
160
100-16
21
19-3/8
19-1/2
4
166
100-20
24-1/2
22-7/8
23
4
184
120-16
21
19-3/8
19-1/2
5
178
120-20
24-1/2
22-7/8
23/
5
194
140-20
24-1/2
22-7/8
23
5
204
A
CAUTION
Air
for
combustion
must
not
be
contaminated
by
halogen
compounds,
which
include
fluoride,
chloride,
bromide
and
iodide.
These
elements
are
found
in
aerosol
sprays,
deter¬
gents,
bleaches,
cleaning
solvents,
salts,
air
fresheners,
and
other
household
products.
All
fuel-burning
equipment
must
be
supplied
with
air
for
combus¬
tion
of
the
fuel.
Sufficient
air
MUST
be
provided
to
insure
there
will
not
be
a
negative
pressure
in
the
equipment
room
or
space.
In
addition,
a
positive
seal
MUST
be
made
between
the
furnace
cabinet
and
the
return-air
duct
to
prevent
pulling
air
from
the
burner
area
and
draft
safeguard
opening.
A
CAUTION
The
operation
of
exhaust
fans,
kitchen
ventilation
fans,
clothes
dryers,
or
fireplaces
could
create
a
negative
air
pressure
condition
at
the
furnace.
Make-up
air
must
be
provided
for
the
ventilation
devices,
in
addition
to
that
required
by
the
furnace.
Combustion
air
requirements
are
determined
by
whether
the
furnace
is
in
an
UNCONFINED
or
CONFINED
space.
A
confined
space
is
one
whose
volume
is
less
than
50
cubic
ft
per
1000
Btuh
of
the
total
input
rating
for
all
appliances
installed
in
that
space.
UNCONFINED
SPACE
An
unconfined
space
must
have
at
least
50
cubic
ft
for
each
1000
Btuh
of
input
for
all
the
appliances
(i.e.
furnaces,
clothes
dryer,
water
heaters,
etc.)
in
the
space.

Related product manuals