Fig. 30 — 42DC Hi-Performance Hideaway With Plenum, Bottom Return
UNIT
SIZE
42DC
DIMENSIONS in. [mm]
a,b,c,d,e,f,g,h
NOTE(S):
a. Right-hand units shown, left-hand opposite.
b. All dimensions are ± .25 [6]. Drawing not to scale.
c. Product specifications are subject to change without notice.
d. Drip lip recommended. Provided when valve package is ordered.
e. Control box size and position may vary. Consult factory.
f. Position may vary.
g. Service access is located on the front of the control box.
h. Knockouts on the bottom and side of the control box for incoming connections.
QUANTITY/UNIT
A A' B C D E F G Blower Motor
06 23 [584] 32 [813] 14 [356]
13-1/2
[343]
17 [432]
21 [533] 25-1/2
[648] 18-3/4
[476]
11
08 28 [711] 37 [940] 19 [483]
13-1/2
[343]
22 [559]
26 [660] 30-1/2
[775] 23-3/4
[603]
11
10 32 [813] 42 [1067] 23 [584]
14-1/2
[368]
26 [660]
30 [762] 34-1/2
[877] 27-3/4
[705]
11
12 37 [940] 47 [1194] 28 [711]
14-1/2
[368]
31 [787]
35 [889] 39-1/2
[1004] 32-3/4
[832]
22
14 42 [1067] 52 [1321] 33 [838]
14-1/2
[368]
36 [914]
40 [1016] 44-1/2
[1131] 37-3/4
[959]
22
16 47 [1194] 56 [1422] 38 [965]
13-1/2
[343]
41 [1041]
45 [1143] 49-1/2
[1258] 42-3/4
[1086]
22
18 52 [1321] 52 [1321] 43 [1092]
14-1/2
[368]
46 [1168]
50 [1270] 54-1/2
[1385] 47-3/4
[1213]
22
20 56 [1422] 66 [1676] 47 [1194]
14-1/2
[368]
50 [1270]
54 [1372] 58-1/2
[1487] 51-3/4
[1314]
22
E
C
13-3/8
[341]
1 [25] Supply
Duct Collar
1 [26]
16-3/8
[417]
Filter Removal
(Both Slides)
14
[1455]
1 [25] Filter
2-1/2 [65]
19
[483]
16-1/2
[418]
28-1/2
[722]
29-1/2
[748]
Return
Air
Front Mounted Holes
D
Top View
Front View
Right Side View
Drain Pan (Abbreviated View)
Resilient Mount Grommet
with 3/8 [10] Dia. Hole
Qty 4
A'
Optional
Extended
Drain Pan
7/8 [22] O.D.
Condensate
Drain
Optional 5/8 [16] O.D.
Tell-Tale Drain Connection
(Available on standard and
extended drain pans.)
Chilled/Hot
Water Supply
and Return
Connections
Optional Drip Lip
Mounting Location
No Valve Pkg
Shipped loose
(See Note d)
Control Box
(See Notes e,h)
Optional Service
Switch
4-1/2
[114]
7/8
[21]
28-5/8
[727]
3/4
[19]
F
Rear Mounted Holes
6
[152]
9-1/4
[236]
26-1/4
[666]
1-7/8
[47]
3-1/8
[79]
4-1/2
[114]
B
A
16-3/8
[417]
Supply
Air
2-5/8
[67]
1-1/8
[28]
13
[329]
1-1/8
[28]
G

Table of Contents